Purpose, Responsibility, Innovation and Devotion.

 

 

 

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsCoating Thickness Gauge

(A-SCAN) Ultrasonic Color Waveform Corrosion Thickness Gauge

(A-SCAN) Ultrasonic Color Waveform Corrosion Thickness Gauge

    • (A-SCAN) Ultrasonic Color Waveform Corrosion Thickness Gauge
    • (A-SCAN) Ultrasonic Color Waveform Corrosion Thickness Gauge
  • (A-SCAN) Ultrasonic Color Waveform Corrosion Thickness Gauge

    Product Details:

    Place of Origin: China
    Brand Name: Pride
    Model Number: TG330

    Payment & Shipping Terms:

    Minimum Order Quantity: 1
    Price: negotiation
    Delivery Time: 10-15 work days
    Payment Terms: L/C, T/T, Western Union, MoneyGram
    Contact Now
    Detailed Product Description
    Repeatability: ±0.05mm Size: 153mm×76mm×37mm (H×W×D)
    Weight: 280g, Including Batteries Measuring Rate: 4 Times Per Second
    Operating Language: English Power: Two AA Alkaline Batteries
    Name: (A-SCAN) Ultrasonic Color Waveform Corrosion Thickness Gauge Display Screen: 320×240 Dot Matrix, 2.4 Inch Color Screen

    Ultrasonic Color Waveform Corrosion Thickness Gauge

     

    (A-SCAN) TG330

     

    LIVE COLOR WAVEFORM(A-SCAN).
    CONTROL OF GAIN, BLANKING, GATE, RANGE, DELAY, RF AND RECTIFY MODES.
    DYNAMIC WAVEFORM AND THICKNESS COLOR CHANGE ON ALARM.

     

    If the ordinary thickness gauges are incompetent in the rough applications. Please turn to our TG330, which will maximize measurement performance for challenging applications and provide you with the cost-effective measurement solutions.

     

    PRINCIPLES

     

    The ordinary ultrasonic thickness gauge with the principle pulse/echo method could do the test by the following two conditions.

    1. The first underside echo must be higher than the gate. (The height of the electrical level

    of the gate is unadjustable)

    2. No other noise waves before the first underside echo are higher than the gate.

    (Otherwise, we will get the thickness where the noise wave are produced)

     

    For some conditions, the above situations could not be satisfied, for example, the highly corrosive near surface, coarse-grain materials(e.g. cast iron), aluminum, small diameter pipes, super thin sheet, super thick plate, rough surface, nonuniform inner structure, defect contained workpiece, lamination and so on which could not be tested by the ordinary gauges.

     

    TG330 will solve the above problems easily.

    1. Make the first underside wave higher than the gate by adjusting the gain and height of the gate.

    2. Invalidate noise waves before the first underside wave by the function of blanking.

     

    Live Color A-Scan

     

    The user could directly see the color waveform of the ultrasonic sound (or A-scan) on the screen, which is quite important for the occasions that we need to check the correctness of the testing results. Many cases will cause wrong testing results or even no readings. We could find the causes easily through the A-scan. Adjust the three parameters of GAIN, BLACKING, GATE, and then we will get the right readings.

     

    The uses for waveform: testing the correctness of thickness readings, finding out the causes of impacting the testing, and adjusting the parameters to solve the problems.

     

    Gain

     

    Adjust the amplification factor of echo signal, increasing and reducing by 1 dB by hand. It is quite effective for acoustic attenuation materials (e.g. cast iron).

     

    BLANKING

     

    Invalidate the waves within the red blanking strip, and omit the useless noise waves that impact the measuring like the waves caused by the rough surface or nonuniform inner structure.

    (A-SCAN) Ultrasonic Color Waveform Corrosion Thickness Gauge

     

    ADJUSTABLE GATE


    The gauge will get the reading only when the wave is higher than the gate. So the adjustable height of gate is very important, especially for the applications of low echo signals (e.g. super thin sheet, super thick plate).

     

    (A-SCAN) Ultrasonic Color Waveform Corrosion Thickness Gauge

     

    RED ARROWHEAD


    A red arrowhead is pointing at the measuring point in A-scan mode, and the thickness value is the horizontal ordinate of this point. It will help to judge the correctness of the reading. We will get the right reading if the red arrowhead is pointing at the advancing front of the first underside echo.
     

    RANGE


    Adjust the wave scope on the screen, and they are visually compressed or spreaded. Without the correct wave range, the wave may be out of the screen, but the right reading will still show.
     

    DELAY


    Adjust the initial position of the wave on the screen, the wave will be moved visually. Without the correct wave range, the wave may be out of the screen, but the right reading will still show.
    The functions of RANGE and DELAY could magnify any section of the wave showing on the screen.
     

    RECTIFICATION MODES


    Four modes selectable: RF, Half-Wave Positive, Half-Wave Negative and Full Wave.
    RF: describe the whole echo waveform.
    Half-Wave Positive: show the Half-Wave Positive without the Half-Wave Negative.
    Half-Wave Negative: upturn the Half-Wave Negative and dispose of the Half-Wave Positive.
    Full Wave: show both the Half-Wave Positive and upturned Half-Wave Negative.

    (A-SCAN) Ultrasonic Color Waveform Corrosion Thickness Gauge

     

    ALARM MODE

    The high limit and low limit of the Alarm could be set. Dynamic waveform and thickness reading color change on alarm.

    (A-SCAN) Ultrasonic Color Waveform Corrosion Thickness Gauge

     

    REDUCTION RATE MEASURE

     

    Differential Mode and Reduction Rate Mode are standard Features. Differential Mode shows the thickness variation from a pre-set thickness value. Reduction Rate calculates and displays the percent of thickness reduction after a material thinning process.
     

    MIN./MAX. MODES


    On this mode, the current thickness, minimum thickness and the maximum thickness will be shown on the screen at the same time. You could drag the probe along the surface of the work, and the minimum and maximum will be shown automatically on the screen.

     

    (A-SCAN) Ultrasonic Color Waveform Corrosion Thickness Gauge  (A-SCAN) Ultrasonic Color Waveform Corrosion Thickness Gauge  (A-SCAN) Ultrasonic Color Waveform Corrosion Thickness Gauge

      
    Reading in white means couplant well Differential Mode and Reduction Rate Mode Min./Max.modes, reading in red means alarm


    OPTIONAL VERIOUS PROBE


    The V-path correction program for several probes is built in the gauge, including standard probe, small diameter tube probe, fingertip probe, cast iron probe, and high temperature probe. The frequency is ranging from 2 to 10MHz, and the size for the crystal from 4 to12mm.

     

    Generally speaking, transducers with higher frequencies and smaller diameters allow measurements of thinner or curved parts and enhance the accuracy of the measurement.

     

    (A-SCAN) Ultrasonic Color Waveform Corrosion Thickness Gauge

    Specifications and Accessories
    Operating Principle:
    Ultrasonic pulse/echo method with dual-element probes.
    Measuring Range:
    0.5-508mm; 0.02-20 inch
    Depending on probe, material, surface condition and temperature
    Unites and Resolution:
    mm- 0.01; 0.1
    inch- 0.001; 0.01
    Display Modes
    Digital Thickness Readout
    A-scan or Waveform
    Min./ Max. Capture
    D-Value/ Reduction
    V-path Correction:
    Automatic V-path Correction,
    compensating the nonlinear
    characteristic of dual-element
    Measuring Error:
    ±0.05mm (up to 25mm)
    ±0.2% H (up to 100mm)
    ±0.5% H (above 100mm)
    Note: H is the height of the material.
    Repeatability:
    ±0.05mm

     

    Display Screen:
    320×240 dot matrix,
    2.4 inch color screen
    Measuring Rate :
    4 times per second
    Material Velocity Range:
    500~9999 m/s; 0.0197~0.3937 in/us
    Operating Languages:
    English
    Warranty:
    2 years limit
    Power Supply:
    Two AA alkaline batteries
    Operating Time:
    More than 36 hours,
    with two AA alkaline batteries
    Auto Shut-off:
    After 5 minutes of non-use
    Operating Temperature:
    -10℃~+50℃
    Specification to -20 on request
    Size:
    153mm×76mm×37mm (H×W×D)
    Weight:
    280g, including batteries
    Standard Package:
    UTG-142 thickness gauge
    Standard probe
    Carrying case
    Two 1.5V AA alkaline batteries
    Couplant
    Operating manual
    Accessories:
    Several selectable probes; test block; couplants and high temperature couplant

    Contact Details
    Shenzhen Pride Instrument Inc.

    Contact Person: Kally Tang

    Tel: +8615170732837

    Send your inquiry directly to us (0 / 3000)

    Other Products